Description
James Laird-Wah
2015-07-28 10:08:14 UTC
The developer who wrote that code is no longer around; I'm looking at this in detail for the first time myself, so I also have some problems trying to understand how the connection needs to be closed correctly. The patch you sent just seems to ensure that the connection gets serviced longer than usual, so the real problem must be some missing code that waits for the proper termination of the connection. In Wireshark, I see this at the end (copied one-by-one with context menu->Copy->Summary (Text) - if there's a better way I'm all ears): 103 2.569266000 localhost () Nokia_1e:ad:30 (Nokia N97 mini) L2CAP 17 Sent Disconnection Request (SCID: 0x0041, DCID: 0x0041) 104 2.573606000 controller host HCI_EVT 8 Rcvd Number of Completed Packets 105 2.575667000 Nokia_1e:ad:30 (Nokia N97 mini) localhost () L2CAP 17 Rcvd Disconnection Response (SCID: 0x0041, DCID: 0x0041) 106 4.579482000 host controller HCI_CMD 7 Sent Disconnect 107 4.580612000 controller host HCI_EVT 7 Rcvd Command Status (Disconnect) 108 4.666611000 controller host HCI_EVT 7 Rcvd Disconnect Complete This looks normal to me. What's your corresponding trace? When you say "the last message (acknowledgement) from SyncEvolution does not go over the OBEX link" are you talking about the SyncML message or some lower-level OBEX/RFCOMM/whatever message? Created attachment 117682 [details] [review] wait before cancelling during shutdown After adding debug messages and looking at the code more closely, I can imagine that the (normal) shutdown() call might cancel the transfer of the last SyncML message if it happens too quickly after the send(). Without the additional wait(true) in shutdown(), the debug output shows a OBEX_EV_LINKERR. That error goes away when waiting for the OBEX_EV_REQDONE for the OBEX_CMD_PUT. However, the phones that I have tested with so far never had the problem and even when there is such a OBEX_EV_LINKERR, the N97 mini that I was testing with now didn't seem to care. James, does this patch fix the problem for you? I'm taking the patch into SyncEvolution 1.5.2 release candidates. Some more testing with that (once available as binaries) would be good. Fixed as part of 1.5.2. |
Use of freedesktop.org services, including Bugzilla, is subject to our Code of Conduct. How we collect and use information is described in our Privacy Policy.