Description Arun Raghavan 2013-12-06 14:10:14 UTC
If the BATCH flag is set on a PCM, we know that avail updates will happen at period granularity. In this situation, we should update the rewind_safeguard to be at least period-sized.
Comment 1 Raymond 2014-06-20 11:43:47 UTC
could it be bug of snd-usb-audio driver which update hwptr in 1ms interval ?



since 1ms of 44100Hz contains 44.1 samples, the driver should use 10ms period
Comment 2 GitLab Migration User 2018-07-30 10:13:03 UTC
-- GitLab Migration Automatic Message --

This bug has been migrated to freedesktop.org's GitLab instance and has been closed from further activity.

You can subscribe and participate further through the new bug through this link to our GitLab instance: https://gitlab.freedesktop.org/pulseaudio/pulseaudio/issues/273.