Description Aleksander Morgado 2017-03-14 23:08:54 UTC
Looks like sending CSIM commands just after a SIM-PIN unlock (may) end up locking the TTY completely, see attached logs.
Comment 1 Aleksander Morgado 2017-03-14 23:09:22 UTC
Created attachment 130225 [details]
Logs showing the TTY lockup
Comment 2 Aleksander Morgado 2017-03-14 23:10:07 UTC
This is with a Telit LE866-SV1, rev. 23.00.002 (M0A.00020), btw.
Comment 3 Aleksander Morgado 2017-03-16 21:37:15 UTC
Fix pushed to git master as 9384817a14c8706909f619e773a76edd65a0fdef, also cherry-picked for mm-1-6.