Hi, reporting downstream bug: https://bugs.launchpad.net/ubuntu/+source/upower/+bug/1590244 summary: system is shut down on upower restart because it thinks the UPS battery is empty. It can take maybe 20s before it knows of the battery state (as when starting up the machine), so it has plenty of time to take the system down... there should be a grace period when starting the daemon and not do silly things like this
-- GitLab Migration Automatic Message -- This bug has been migrated to freedesktop.org's GitLab instance and has been closed from further activity. You can subscribe and participate further through the new bug through this link to our GitLab instance: https://gitlab.freedesktop.org/upower/upower/issues/9.
Use of freedesktop.org services, including Bugzilla, is subject to our Code of Conduct. How we collect and use information is described in our Privacy Policy.